Simulation run time: 00:00:13

Wednesday, April 22, 2020 2:03:40 PM

Assembly Geometry & Materials

Material Summary

PropertyValue
DescriptionMycelium 1
Density0.236215 slug/ft3
Elastic Modulus41770.9 lb/ft2
Default Failure Criterionvon Mises
Tensile Yield Strength4896 lb/ft2
Ultimate Tensile Strength208.854 lb/ft2
Ultimate Compressive Strength2592 lb/ft2

Component Geometry Summary

QuantityUnit
Component 9a6d0dd1-6e41-46c1-af2b-c2c9f953be48
Material Mycelium 1
Mass 495.705 slug
Bounding Box {27.2276, 46.3055, -2.03609e-14}-{29.2456, 47.7222, 2.46763}

Loads & Restraints

Load Summary

DescriptionTypeDefinition
200 lbsVector Force{123.081,0,-571.819} lb

Restraint Summary

DescriptionDefinition
Restraint 7X-Fixed, Y-Fixed, Z-Fixed

Simulation Summary

Simulation run time: 00:00:13

Settings

Basis Functions
Degree1
nx28
ny20
nz33
Element size{0.0814421, 0.0814421, 0.0814421}
Resolution setting10000
Computation Box
min. corner{27.1373, 46.2398, -0.0695563}
max. corner{29.3362, 47.7872, 2.53659}
Linear Solver
Solver Auto: DSS @ < 100000

Units

QuantityUnit
Lengthft
Massslug
Forcelb
Times

Simulation Results

Displacements

Displacement Summary

AmountLocation
Minimum2.1693E-006 ft28.0315, 46.9841, 0.0000
Maximum1.0724E-002 ft29.0334, 47.0536, 2.3784

Von Mises Stress

Von Mises Stress Summary

AmountLocation
Minimum5.8713E-001 lb/ft227.2832, 46.3314, 1.3611
Maximum7.0079E+002 lb/ft229.0969, 46.4248, 0.0000

Danger Level

Danger Level Summary

AmountLocation
Minimum1.1992E-004 27.2832, 46.3314, 1.3611
Maximum1.4313E-001 29.0969, 46.4248, 0.0000

Results Extrema

MinimumMaximum
X-Displacement-7.3716E-006 ft8.2425E-003 ft
Y-Displacement-8.6970E-004 ft9.2872E-004 ft
Z-Displacement-6.9564E-003 ft3.4276E-006 ft
Total Displacement2.1693E-006 ft1.0724E-002 ft
Von Mises Stress5.8713E-001 lb/ft27.0079E+002 lb/ft2
Max. Principal Stress-6.9345E+002 lb/ft24.4259E+002 lb/ft2
Mid. Principal Stress-7.3286E+002 lb/ft22.5055E+002 lb/ft2
Min. Principal Stress-1.3952E+003 lb/ft21.8978E+002 lb/ft2

CAUTION

Design decisions require experimental data and substantial experience; they should never be made based solely on a software simulation. Simulation is not intended to replace physical testing of prototypes, which is required to validate any design.